Emc QLogic Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware Emc QLogic. EMC QLogic User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 104
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
EMC Corporation
Corporate Headquarters
:
Hopkinton, MA 01748 -9103
1
-508 -435 -1000
www.emc.com
EMC Fibre Channel with
QLogic Host Bus Adapters in the
Windows Environment
P/N 300-001-164
REV A07
QLogic_Windows.book Page i Thursday, March 10, 2005 10:31 AM
Zobrazit stránku 0
1 2 3 4 5 6 ... 103 104

Shrnutí obsahu

Strany 1 - Windows Environment

EMC CorporationCorporate Headquarters:Hopkinton, MA 01748 -91031-508 -435 -1000www.emc.comEMC Fibre Channel withQLogic Host Bus Adapters in theWindow

Strany 2

11-2EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentIntroductionUnderstanding Persistent Binding in a Fabric EnvironmentPersistent bindin

Strany 3 - Contents

BB-2EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentTroubleshootingProblems and SolutionsProblem 1Error Message ID: 51 in event viewer wh

Strany 4

BProblems and SolutionsB-3TroubleshootingSolution Upgrade to the latest HBA driver. This was corrected for Windows 2000 in 8.2.2.25 and later drivers.

Strany 5 - Appendix B Troubleshooting

BB-4EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentTroubleshootingProblem 7When using SANSurfer 2.0.25 to update to BIOS 1.4x, you recei

Strany 6

EMC Fibre Channel with QLogic HBAs in the Windows Environmenti-1Aadapter BIOS 2-2adapter topology 2-13Bbinding, persistent 1-2, 1-3BIOSadapter 2-2

Strany 7

EMC Fibre Channel with QLogic HBAs in the Windows Environmenti-2IndexHhard zoning (switch) 3-21HBA driver 2-14HBA, boot, replacing 3-36HBA, install

Strany 8 - AVANT GARDE

1Understanding Persistent Binding in a Fabric Environment1-3Introduction\\PHYSICALDRIVE0, \\PHYSICALDRIVE1, and \\PHYSICALDRIVE2. The number is assign

Strany 9

11-4EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentIntroductionThe next figure shows the same host after the cable attached to HBA0 has

Strany 10 - Introduction

Installing and Configuring the HBA Driver2-12Invisible Body Tag This chapter describes the procedures for installing an EMC-approved QLogic host b

Strany 11

22-2EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA DriverIntroductionThe procedure described here was

Strany 12

2Installing an HBA2-3Installing and Configuring the HBA DriverInstalling an HBAFollow the instructions included with your HBA. The HBA installs into a

Strany 13 - Configuring the HBA

22-4EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA Driver4. Label each cable to identify the HBA and

Strany 14

2Installing an HBA2-5Installing and Configuring the HBA Driverfields to select the correct CX200-Series direct-connect dual-host cluster-compatible fi

Strany 15 - Installing an HBA

22-6EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA DriverIf later you wish to return the jumper(s) to

Strany 16 - Clustering Configurations

2Installing an HBA2-7Installing and Configuring the HBA Driver7. Enter a value for the loop ID and press ENTER.8. Press ESC to return to the Configura

Strany 17

EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentiiCopyright © 2001–2005 EMC Corporation. All rights reserved.Updated March 2005EMC believ

Strany 18

22-8EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA DriverEMC HBA SettingsEMC requires configuring the

Strany 19

2EMC HBA Settings2-9Installing and Configuring the HBA DriverConfiguring NVRAM for Stratus ftServersIf you have not received QLogic HBAs with the EMC

Strany 20 - EMC HBA Settings

22-10EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA DriverIgnore any steps that pertain to multiple a

Strany 21 - Configuring NVRAM

2EMC HBA Settings2-11Installing and Configuring the HBA DriverUpdating WhileRunning WindowsTo update while running Windows, refer to QLogic SANSurfer

Strany 22

22-12EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA Driverfile name, note that some BIOS versions mig

Strany 23

2EMC HBA Settings2-13Installing and Configuring the HBA DriverSetting the Topology for QLA22xx/23xx and WindowsWhile using a QLA22xx or QLA23xx HBA fo

Strany 24 - HBA Data Rate

22-14EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA DriverInstalling the HBA DriverTo use EMC storage

Strany 25 - Setting the Topology

2Installing the HBA Driver2-15Installing and Configuring the HBA DriverWindows 2003 STORPort UpdatesCurrently the shipping version of Windows 2003 req

Strany 26 - Installing the HBA Driver

22-16EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA Driver7. Select QLogic QLA2300 (or QLA2200) PCI F

Strany 27 - Windows 2003 STORPort Updates

2Installing the HBA Driver2-17Installing and Configuring the HBA Driver10. Enter the path to the diskette containing the driver (for example, A:\), th

Strany 28 - Windows 2003 Hosts

EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentiiiPreface...

Strany 29

22-18EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA DriverUpdating the HBA Driver in a Windows 2000 o

Strany 30

2Updating the HBA Driver in a Windows 2000 or Windows 2003 Host2-19Installing and Configuring the HBA Driver12. If prompted, click Yes to continue the

Strany 31

22-20EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA DriverUpgrading to Windows 2003 from Windows 2000

Strany 32 - Windows NT 4.0

2Replacing an HBA2-21Installing and Configuring the HBA DriverReplacing an HBAProcedure for Replacing a QLogic HBA in Stratus ftServers without Reboot

Strany 33 - Replacing an HBA

22-22EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA Driver10. Execute the following commands from a c

Strany 34

2Replacing an HBA2-23Installing and Configuring the HBA Driver10. Run symmask refresh to update the director profile tables (in cache) from the databa

Strany 35

22-24EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the HBA DriverQLogic_Windows.book Page 24 Thursday, Mar

Strany 36

Configuring an EMC Boot Device3-13Invisible Body Tag Windows hosts have been qualified for booting from EMC storage array devices interfaced throu

Strany 37 - Boot Device

33-2EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceIntroductionWindows hosts have been qualified for booti

Strany 38

3Introduction3-3Configuring an EMC Boot Device◆ Storage Area Network service/upgrade procedures, such as firmware upgrades or hardware replacementsEMC

Strany 39

EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentivContentsInstallation Procedure for Windows 2000 and Windows 2003 Hosts...

Strany 40 - Boot-from-SAN with MSCS

33-4EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceBoot Crashdump Save to Disk BehaviorIf you system is co

Strany 41 - Configuring the Boot BIOS

3Configuring a Symmetrix Boot Device3-5Configuring an EMC Boot DeviceConfiguring a Symmetrix Boot DeviceThis section describes how to install the Wind

Strany 42

33-6EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot Device5. From the Configuration Settings menu, select Host Ad

Strany 43

3Configuring a Symmetrix Boot Device3-7Configuring an EMC Boot DeviceInstalling the Windows OS onto the Boot DeviceFollow the appropriate steps below

Strany 44

33-8EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot Device7. Some servers use SCSI CD-ROM drives. If your server

Strany 45 - , type fs1: and

3Configuring a Symmetrix Boot Device3-9Configuring an EMC Boot DeviceIf a system contains of mixture of detected and undetected adapters, any existing

Strany 46

33-10EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot Device1. To load the EFI driver onto the HBA, type ew and pr

Strany 47 - <control>

3Configuring a Symmetrix Boot Device3-11Configuring an EMC Boot Device2. At the shell> prompt, type drivers and press ENTER. The list of currently

Strany 48

33-12EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot Device2. Hard Loop Id (hex) = 255 (Note: Only direct-connect

Strany 49

3Configuring a Symmetrix Boot Device3-13Configuring an EMC Boot Devicethere, you can configure your zone(s) on the fabric to allow the HBA to connect

Strany 50 - Flowchart

vEMC Fibre Channel with QLogic HBAs in the Windows EnvironmentContentsStarting a Fresh Installation...

Strany 51

33-14EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceConfiguring a CLARiiON Boot DeviceThis section describ

Strany 52 - Requirements

3Configuring a CLARiiON Boot Device3-15Configuring an EMC Boot DeviceRequirementsSatisfiedStartUnsatisfiedPrepare Storage SystemComplete Requi

Strany 53 - Preparing the Storage System

33-16EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceRequirementsThis section lists supported configuration

Strany 54 - Setting Up the HBA BIOS

3Configuring a CLARiiON Boot Device3-17Configuring an EMC Boot DeviceMedia Requirements Required media includes the following:Refer to Downloading QLo

Strany 55 - Preparing the Fabric

33-18EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceSetting Up the HBA BIOSAfter the HBA is installed in t

Strany 56 - QLogic Corporation

3Configuring a CLARiiON Boot Device3-19Configuring an EMC Boot Device9. Press ESC to exit the Fast!UTIL Options menu.10. Reboot the host.What Next? Th

Strany 57

33-20EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceSoft Zoning These instructions let you configure the s

Strany 58 - Preparing the Server

3Configuring a CLARiiON Boot Device3-21Configuring an EMC Boot Device3. Create a member alias for the boot HBA WWPN. Make sure it is a member alias an

Strany 59 - Boot BIOS

33-22EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DevicePhysical Connectionof Only One SP Port tothe FabricIf

Strany 60

3Configuring a CLARiiON Boot Device3-23Configuring an EMC Boot Device3. To disconnect all SCSI hard disk drives, unplug the power and SCSI bus cables

Strany 61 - Installing Windows

EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentviContentsProblem 5...

Strany 62

33-24EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceDifferent HBA models may display different banners. Be

Strany 63

3Configuring a CLARiiON Boot Device3-25Configuring an EMC Boot DeviceWhen the QLogic BIOS banner (shown in step 1) appears, press CTRL–Q.Different HBA

Strany 64

33-26EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot Device1. Insert a bootable Windows CD-ROM in the drive and r

Strany 65

3Configuring a CLARiiON Boot Device3-27Configuring an EMC Boot DeviceThe Windows Server Setup dialog displays disk partition information (if your syst

Strany 66 - <storagegroupname>

33-28EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceIf your system prompts you to press any key to boot fr

Strany 67 - <storagegroupname

3Configuring a CLARiiON Boot Device3-29Configuring an EMC Boot DeviceWhat Next? From here:◆ If you need to install multipath and failover software, re

Strany 68 - CTRL-Q BIOS

33-30EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot Device2. Create and enable a zone for each additional HBA an

Strany 69

3Configuring a CLARiiON Boot Device3-31Configuring an EMC Boot DeviceConnect host <hostname> to storage group <storagegroupname> (y/n)?&qu

Strany 70 - Starting a Fresh Installation

33-32EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot Device• If there are multiple QLogic HBAs, a list of address

Strany 71

3Configuring a CLARiiON Boot Device3-33Configuring an EMC Boot Device– With FC-series array core code 8.44.x and earlier, you will use the atf_trespas

Strany 72 - Replacing a Boot HBA

EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentviiPrefaceConventions Used inThis GuideEMC uses the following conventions for notes, caut

Strany 73

33-34EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot Devicee. Find this Device Type line and note the LUN value.

Strany 74 - Known Issues

3Boot Time and LUN Availability3-35Configuring an EMC Boot Devicebefore the storage system is ready to respond. If this occurs, the server will not be

Strany 75 - QLogic QLA4010 iSCSI

33-36EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceReplacing a Boot HBAIf a boot HBA fails, you can repla

Strany 76

3How a Server Responds to Failure in the Boot LUN Path3-37Configuring an EMC Boot DeviceHow a Server Responds to Failure in the Boot LUN PathFailure i

Strany 77

33-38EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentConfiguring an EMC Boot DeviceKnown IssuesBe aware of these issues:◆ QLogic BIOS 1.2

Strany 78

Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)4-14Invisible Body Tag The QLA4010/4010C is an iSCSI HBA that provides PCI connectivi

Strany 79

44-2EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)Installing the HBA Drive

Strany 80

4Windows 2003 STORPort Updates4-3Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)6. In the next dialog, click ReInstall Driver, and then,

Strany 81

44-4EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)Updating the HBA Driver

Strany 82

4Updating the HBA Driver in a Windows 2000 or Windows 2003 Host4-5Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)14. If the system reque

Strany 83

viiiEMC Fibre Channel with QLogic HBAs in the Windows EnvironmentPrefaceTypographical ConventionsEMC uses the following type style conventions in this

Strany 84

44-6EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)Using the QLogic iSCSI S

Strany 85

4Using the QLogic iSCSI SANSurfer Application to Configure iSCSI Devices4-7Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)which host to

Strany 86

44-8EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)Configuring iSNS setting

Strany 87

4Configuring iSNS settings for QLA40104-9Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)To update firmware on your iSCSI HBA, click the

Strany 88

44-10EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)The firmware will be lo

Strany 89 - ENTER. Under the

4Configuring iSNS settings for QLA40104-11Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)To configure your iSCSI targets, click the Targ

Strany 90

44-12EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)You may add as many tar

Strany 91

4Configuring iSNS settings for QLA40104-13Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)rity password. The default password is “config

Strany 92

44-14EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)Installing and Configur

Strany 93 - Third-Party Software

4Installing and Configuring the QLA4010 iSCSI HBA to boot from an EMC Storage Array4-15Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)2.

Strany 94 - Manager Software or Agents

Introduction1-11Invisible Body TagThis document describes the procedures for installing an EMC-approved QLogic host bus adapter (HBA) into a Windows N

Strany 95 - SANSurfer Version

44-16EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)17. Press ESC to return

Strany 96 - VERITAS Volume Manager 3.0

4Installing and Configuring the QLA4010 iSCSI HBA to boot from an EMC Storage Array4-17Installing and Configuring the QLogic QLA4010 iSCSI HBA (TOE)Fr

Strany 97 - VERITAS Foundation Suite 4.2

44-18EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentInstalling and Configuring the QLogic QLA4010 iSCSI HBA (TOE)QLogic_Windows.book Pa

Strany 98

Third-Party SoftwareA-1AInvisible Body TagThis appendix contains additional information about third-party software used with Windows hosts.◆ QLogic SA

Strany 99 - Troubleshooting

AA-2EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentThird-Party SoftwareQLogic SANSurfer SANBlade ManagerStratus ftServers are not suppor

Strany 100 - Problems and Solutions

AQLogic SANSurfer SANBlade ManagerA-3Third-Party SoftwareSANSurfer Version HistorySANSurfer versions include:◆ 2.0.21 — Initial ReleaseThe SANSurfer s

Strany 101 - Problem 6

AA-4EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentThird-Party SoftwareVERITAS Volume Manager 3.x for Windows 2000Refer to the latest EM

Strany 102 - Problem 8

AVERITAS Volume Manager 3.x for Windows 2000A-5Third-Party SoftwareVERITAS Volume Manager 3.1 and VERITAS DMPIf using PowerPath with VERITAS Volume Ma

Strany 103

AA-6EMC Fibre Channel with QLogic HBAs in the Windows EnvironmentThird-Party SoftwareQLogic_Windows.book Page 6 Thursday, March 10, 2005 10:31 AM

Strany 104

TroubleshootingB-1BInvisible Body TagThis appendix contains information on troubleshooting problems. ◆ Problems and Solutions.......

Komentáře k této Příručce

Žádné komentáře